免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

一步法人胱抑素C(Cys-C)酶聯(lián)免疫吸附檢測試劑盒
ELK005ES
規格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: EasyStep Human Cys-C(CystatinC) ELISA Kit
Reactivity: Human
Alternative Names: CST3; Cystatin 3; ARMD11; Post-Gamma-Globulin
Assay Type: Sandwich
Sensitivity: 25 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.1-5000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Tags & Cell Markers;Cell Biology;Stem Cells;Cardiovascular
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Cys-C, and the Human Cys-C standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human Cys-C. After TMB substrate solution is added, only those wells that contain Human Cys-C and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Cys-C in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
5000.00 2.781 2.716
2500.00 1.701 1.637
1250.00 0.906 0.842
625.00 0.508 0.443
312.50 0.319 0.254
156.25 0.177 0.113
78.13 0.120 0.056
0.00 0.064 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Cys-C and the recovery rates were calculated by comparing the measured value to the expected amount of Cys-C in samples.
Matrix Recovery range Average
serum(n=5) 88-99% 94%
EDTA plasma(n=5) 102-110% 104%
Heparin plasma(n=5) 98-104% 101%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cys-C and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-106% 88-102% 85-101% 96-107%
EDTA plasma(n=5) 90-103% 94-108% 90-106% 98-105%
Heparin plasma(n=5) 91-100% 98-107% 92-108% 93-102%

產(chǎn)品成分表

關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
浦县| 石柱| 贵阳市| 伊金霍洛旗| 陕西省| 阿拉善右旗| 温宿县| 遂溪县| 水城县| 鹤山市| 临澧县| 资兴市| 祥云县| 根河市| 仙桃市| 长乐市| 岢岚县| 北碚区| 丰顺县| 丹东市| 鄂托克旗| 弥渡县| 巩留县| 清水河县| 望都县| 漯河市| 峨边| 建湖县| 福海县| 青神县| 环江| 托里县| 区。| 孟村| 华池县| 清徐县| 岫岩| 威信县| 永和县| 竹溪县| 行唐县|