免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胞質(zhì)型磷脂酶A2(cPLA2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK0479
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human cPLA2(Cytosolic Phospholipase A2) ELISA Kit
Reactivity: Human
Alternative Names: PLA2G4; cPLA2; cPLA2-alpha
Assay Type: Sandwich
Sensitivity: 13.7 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, saliva, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase
Uniprot ID: P47712
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human cPLA2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human cPLA2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human cPLA2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human cPLA2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.043 1.956
1000.00 1.543 1.456
500.00 1.193 1.106
250.00 0.933 0.846
125.00 0.541 0.454
62.50 0.323 0.236
31.25 0.226 0.139
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant cPLA2 and the recovery rates were calculated by comparing the measured value to the expected amount of cPLA2 in samples.
Matrix Recovery range Average
serum(n=5) 84-96% 90%
EDTA plasma(n=5) 78-94% 86%
Heparin plasma(n=5) 87-95% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of cPLA2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-101% 82-98% 89-102%
EDTA plasma(n=5) 83-96% 79-93% 81-93% 86-98%
Heparin plasma(n=5) 92-101% 88-102% 87-102% 93-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
南乐县| 拜城县| 海丰县| 定兴县| 湖州市| 垣曲县| 武定县| 新田县| 会东县| 乌什县| 东至县| 北宁市| 鄄城县| 大英县| 洛浦县| 修水县| 安陆市| 宜黄县| 深州市| 雷波县| 恭城| 扶余县| 茌平县| 岑溪市| 岢岚县| 永安市| 磴口县| 子长县| 南宁市| 凤冈县| 清水县| 洪湖市| 罗平县| 大同县| 股票| 信丰县| 洱源县| 永嘉县| 孝感市| 西华县| 仪征市|