免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠半胱氨酸蛋白酶抑制劑3(CST3)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1046
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse CST3(Cystatin 3) ELISA Kit
Reactivity: Mouse
Alternative Names: Cys-C; Cystatin C; Gamma Trace; Post-Gamma-Globulin; Neuroendocrine Basic Polypeptide; Amyloid Angiopathy And Cerebral Hemorrhage
Assay Type: Sandwich
Sensitivity: 0.126 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Kidney biomarker;Urology;
Uniprot ID: P21460
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CST3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CST3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CST3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CST3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.082 1.895
10.00 1.761 1.574
5.00 1.251 1.064
2.50 0.862 0.675
1.25 0.503 0.316
0.63 0.401 0.214
0.32 0.224 0.037
0.00 0.187 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CST3 and the recovery rates were calculated by comparing the measured value to the expected amount of CST3 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 89-107% 98%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CST3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 79-96% 87-103% 90-99%
EDTA plasma(n=5) 88-97% 96-105% 91-103% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 79-95% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
平定县| 金塔县| 巴林左旗| 屏山县| 仁怀市| 唐河县| 广河县| 古交市| 子洲县| 都兰县| 子洲县| 固始县| 利辛县| 五家渠市| 苍南县| 巴楚县| 淮安市| 台湾省| 华安县| 邹平县| 隆尧县| 沾益县| 旅游| 南丰县| 洛扎县| 永康市| 通化县| 措美县| 阳信县| 丹凤县| 中卫市| 海南省| 麻栗坡县| 射阳县| 怀集县| 宝鸡市| 周至县| 陆丰市| 林周县| 枝江市| 会宁县|