免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產品中心

人補體成分5a(C5a)酶聯(lián)免疫吸附檢測試劑盒
ELK1051
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human C5a(Complement Component 5a) ELISA Kit
Reactivity: Human
Alternative Names: Complement Component 5a
Assay Type: Sandwich
Sensitivity: 27 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Immune molecule;Autoimmunity;
Uniprot ID: P01031
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human C5a. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human C5a. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human C5a, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human C5a in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.073 1.987
2500.00 1.770 1.684
1250.00 1.484 1.398
625.00 1.138 1.052
312.50 0.617 0.531
156.25 0.436 0.350
78.13 0.215 0.129
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant C5a and the recovery rates were calculated by comparing the measured value to the expected amount of C5a in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 78-97% 87%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C5a and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 82-96% 87-105% 87-92%
EDTA plasma(n=5) 93-102% 86-92% 96-105% 89-97%
Heparin plasma(n=5) 90-103% 97-106% 82-90% 92-101%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
射洪县| 囊谦县| 新密市| 五寨县| 隆安县| 堆龙德庆县| 江陵县| 马鞍山市| 民权县| 固原市| 长宁县| 双柏县| 伽师县| 德钦县| 阳信县| 石台县| 贵阳市| 金山区| 长宁县| 邵阳市| 阿图什市| 浠水县| 错那县| 宾阳县| 乐昌市| 资阳市| 得荣县| 虹口区| 新乡县| 工布江达县| 长寿区| 盘山县| 龙胜| 赤水市| 永清县| 囊谦县| 河津市| 龙游县| 湖南省| 龙陵县| 临沧市|