免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人纖溶酶原(Plg)酶聯(lián)免疫吸附檢測試劑盒
ELK1080
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human Plg(Plasminogen) ELISA Kit
Reactivity: Human
Alternative Names: PL; Plasmin; Activation peptide; Angiostatin
Assay Type: Sandwich
Sensitivity: 0.147 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Hematology;
Uniprot ID: P00747
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Plg. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Plg. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Plg, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Plg in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.108 2.021
10.00 1.643 1.556
5.00 1.216 1.129
2.50 0.847 0.760
1.25 0.593 0.506
0.63 0.342 0.255
0.32 0.206 0.119
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Plg and the recovery rates were calculated by comparing the measured value to the expected amount of Plg in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plg and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 82-96% 87-98% 93-101%
EDTA plasma(n=5) 88-102% 86-92% 91-103% 89-97%
Heparin plasma(n=5) 85-94% 92-101% 87-96% 82-90%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
石泉县| 弋阳县| 蚌埠市| 无锡市| 贺州市| 石楼县| 龙里县| 英超| 三原县| 涿州市| 台南县| 乐陵市| 启东市| 肇州县| 上高县| 山西省| 武陟县| 台州市| 榆树市| 滕州市| 彭阳县| 江北区| 射洪县| 布尔津县| 南召县| 石城县| 体育| 屏边| 察隅县| 乌拉特中旗| 盖州市| 张家川| 永顺县| 沅陵县| 昭觉县| 霍州市| 连平县| 集安市| 松桃| 卓资县| 三亚市|