免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠視黃醇結合蛋白4(RBP4)酶聯(lián)免疫吸附檢測試劑盒
ELK1087
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse RBP4(Retinol Binding Protein 4, Plasma) ELISA Kit
Reactivity: Mouse
Alternative Names: PRBP; RBP; Plasma retinol-binding protein
Assay Type: Sandwich
Sensitivity: 0.142 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Endocrinology;Hormone metabolism;
Uniprot ID: Q00724
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse RBP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse RBP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse RBP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse RBP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.984 1.845
10.00 1.584 1.445
5.00 1.296 1.157
2.50 0.958 0.819
1.25 0.632 0.493
0.63 0.364 0.225
0.32 0.238 0.099
0.00 0.139 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant RBP4 and the recovery rates were calculated by comparing the measured value to the expected amount of RBP4 in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of RBP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 96-103% 83-96% 87-98% 85-97%
EDTA plasma(n=5) 78-93% 96-102% 95-103% 89-97%
Heparin plasma(n=5) 85-94% 87-103% 97-105% 79-90%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
甘孜县| 肃南| 吴旗县| 连城县| 毕节市| 航空| 贵港市| 绥棱县| 霸州市| 鄂温| 孟津县| 崇左市| 达日县| 通州市| 灵寿县| 高碑店市| 乌拉特中旗| 当涂县| 玉林市| 吉隆县| 车险| 巴南区| 城口县| 米易县| 海伦市| 惠水县| 靖边县| 朝阳区| 榆树市| 措勤县| 个旧市| 株洲市| 任丘市| 习水县| 明水县| 洪泽县| 龙江县| 梁山县| 柯坪县| 陵川县| 通州区|