免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人肝素結(jié)合性表皮生長(zhǎng)因子(HBEGF)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1090
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human HBEGF(Heparin Binding Epidermal Growth Factor Like Growth Factor) ELISA Kit
Reactivity: Human
Alternative Names: HB-EGF; DTR; DTS; DTSF; HEGFL; Diphtheria Toxin Receptor; Proheparin-binding EGF-like growth factor; Diphtheria toxin receptor
Assay Type: Sandwich
Sensitivity: 6.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: Q99075
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HBEGF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HBEGF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HBEGF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HBEGF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.268 2.127
500.00 1.763 1.622
250.00 1.284 1.143
125.00 0.869 0.728
62.50 0.549 0.408
31.25 0.481 0.340
15.63 0.215 0.074
0.00 0.141 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HBEGF and the recovery rates were calculated by comparing the measured value to the expected amount of HBEGF in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HBEGF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-106% 89-102% 87-98% 85-92%
EDTA plasma(n=5) 88-97% 90-99% 87-103% 82-97%
Heparin plasma(n=5) 85-94% 87-103% 82-94% 78-90%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
安远县| 五寨县| 娄底市| 陆丰市| 广安市| 佳木斯市| 栾城县| 海门市| 婺源县| 衡阳县| 远安县| 岳普湖县| 古蔺县| 宁南县| 铅山县| 涞源县| 兴山县| 临夏县| 衡南县| 安西县| 陈巴尔虎旗| 呼伦贝尔市| 宁河县| 尉氏县| 新干县| 桑日县| 河西区| 广昌县| 菏泽市| 长宁区| 论坛| 宝鸡市| 舟曲县| 通海县| 洛南县| 淮滨县| 宁都县| 安塞县| 肥乡县| 内乡县| 贵定县|