免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人載脂蛋白E(APOE)酶聯(lián)免疫吸附檢測試劑盒
ELK1099
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human APOE(Apolipoprotein E) ELISA Kit
Reactivity: Human
Alternative Names: Apo-E; AD2; Apoprotein; Alzheimer Disease 2(E4-Associated,Late Onset
Assay Type: Sandwich
Sensitivity: 1.8 ng/mL
Standard: 300 ng/mL
Detection Range: 4.69-300 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;Hepatology;
Uniprot ID: P02649
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human APOE. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human APOE. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human APOE, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human APOE in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
300.00 1.995 1.882
150.00 1.487 1.374
75.00 0.976 0.863
37.50 0.752 0.639
18.75 0.517 0.404
9.38 0.324 0.211
4.69 0.215 0.102
0.00 0.113 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant APOE and the recovery rates were calculated by comparing the measured value to the expected amount of APOE in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 83-97% 90%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of APOE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 83-96% 87-98% 82-95%
EDTA plasma(n=5) 98-106% 86-99% 78-95% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
庆元县| 万源市| 定西市| 浪卡子县| 银川市| 大邑县| 贵定县| 旌德县| 奈曼旗| 乐平市| 交城县| 会东县| 湖口县| 武强县| 竹山县| 当涂县| 昌乐县| 井陉县| 巴彦县| 河北区| 陇南市| 塔河县| 清原| 阿拉善右旗| 内乡县| 铜川市| 罗平县| 浦北县| 宁远县| 菏泽市| 天气| 张家港市| 镇雄县| 青龙| 宁德市| 克东县| 湖南省| 崇信县| 闸北区| 丰都县| 巴林左旗|