免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人皮膚T-細(xì)胞虜獲趨化因子(CTACK)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1107
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human CTACK(Cutaneous T-Cell Attracting Chemokine) ELISA Kit
Reactivity: Human
Alternative Names: CCL27; ILC; SCYA27; ALP; Skinkine; ESkine; PESKY; CTAK; Chemokine(C-C-Motif)ligand 27; Small Inducible Cytokine Subfamily A Member 27; IL-11 R-alpha-locus chemokine
Assay Type: Sandwich
Sensitivity: 12.9 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Dermatology;
Uniprot ID: Q9Y4X3
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CTACK. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CTACK. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CTACK, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CTACK in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.248 2.170
1000.00 1.687 1.609
500.00 0.990 0.912
250.00 0.614 0.536
125.00 0.386 0.308
62.50 0.236 0.158
31.25 0.155 0.077
0.00 0.078 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CTACK and the recovery rates were calculated by comparing the measured value to the expected amount of CTACK in samples.
Matrix Recovery range Average
serum(n=5) 96-107% 102%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CTACK and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-95% 85-96% 93-99% 87-101%
EDTA plasma(n=5) 88-100% 95-103% 89-97% 85-94%
Heparin plasma(n=5) 87-103% 97-105% 79-90% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
韶关市| 丽水市| 西贡区| 东宁县| 鲁甸县| 左贡县| 安多县| 镇原县| 莒南县| 长泰县| 丁青县| 怀来县| 楚雄市| 米林县| 化隆| 普宁市| 威宁| 广宗县| 太保市| 神木县| 石屏县| 阿拉善右旗| 武宣县| 栾川县| 永安市| 皮山县| 陕西省| 滕州市| 古交市| 秦皇岛市| 繁昌县| 兰坪| 大名县| 衡阳县| 盈江县| 于田县| 晴隆县| 望谟县| 通化县| 岳普湖县| 西宁市|