免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人S100鈣結(jié)合蛋白A8(S100A8)酶聯(lián)免疫吸附檢測試劑盒
ELK1125
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human S100A8(S100 Calcium Binding Protein A8) ELISA Kit
Reactivity: Human
Alternative Names: MRP8; MIF; 60B8AG; CAGA; CFAG; CGLA; CP-10; L1Ag; NIF; P8; Calgranulin A; Cystic fibrosis antigen; Leukocyte L1 complex light chain; Migration inhibitory factor-related protein 8
Assay Type: Sandwich
Sensitivity: 5.6 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;
Uniprot ID: P05109
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human S100A8. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human S100A8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human S100A8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human S100A8 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 1.984 1.877
500.00 1.579 1.472
250.00 1.096 0.989
125.00 0.807 0.700
62.50 0.456 0.349
31.25 0.336 0.229
15.63 0.218 0.111
0.00 0.107 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A8 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A8 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-94% 85-96% 89-100% 85-96%
EDTA plasma(n=5) 85-94% 87-101% 86-97% 88-95%
Heparin plasma(n=5) 92-101% 87-98% 85-92% 79-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
若羌县| 黄浦区| 信宜市| 海晏县| 富锦市| 红河县| 洞头县| 图们市| 汨罗市| 阿荣旗| 海南省| 广元市| 海原县| 佛坪县| 辛集市| 大悟县| 西林县| 呈贡县| 阳高县| 威信县| 永修县| 福海县| 惠州市| 庆元县| 县级市| 莱芜市| 栾川县| 长泰县| 固镇县| 财经| 谷城县| 教育| 灯塔市| 镇平县| 时尚| 兴安县| 太白县| 赤城县| 太仆寺旗| 黄石市| 英德市|