免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人三葉因子3(TFF3)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1131
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TFF3(Trefoil Factor 3, Intestinal) ELISA Kit
Reactivity: Human
Alternative Names: HITF; ITF3; TFI; HP1.B
Assay Type: Sandwich
Sensitivity: 23.8 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Gastroenterology;
Uniprot ID: Q07654
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TFF3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TFF3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TFF3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TFF3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
4000.00 2.058 1.975
2000.00 1.472 1.389
1000.00 0.839 0.756
500.00 0.752 0.669
250.00 0.553 0.470
125.00 0.319 0.236
62.50 0.129 0.046
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TFF3 and the recovery rates were calculated by comparing the measured value to the expected amount of TFF3 in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 80-95% 87%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TFF3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-96% 85-97% 89-101% 85-97%
EDTA plasma(n=5) 80-101% 87-96% 96-105% 95-103%
Heparin plasma(n=5) 95-103% 87-98% 85-92% 79-96%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
镇宁| 卓资县| 靖江市| 吉木乃县| 三河市| 海口市| 南皮县| 元朗区| 闻喜县| 延川县| 义乌市| 邳州市| 开封市| 曲麻莱县| 抚松县| 当雄县| 涟水县| 新泰市| 福贡县| 瑞昌市| 馆陶县| 临夏县| 稻城县| 汉阴县| 阿合奇县| 苏州市| 巴彦淖尔市| 普安县| 四子王旗| 子长县| 徐州市| 贵港市| 邵东县| 绥芬河市| 漾濞| 穆棱市| 电白县| 涟水县| 乌兰察布市| 金平| 河西区|