免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胰島素樣生長(zhǎng)因子結(jié)合蛋白1(IGFBP1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1137
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human IGFBP1(Insulin Like Growth Factor Binding Protein 1) ELISA Kit
Reactivity: Human
Alternative Names: IBP1; AFBP; IGF-BP25; PP12; Placental Protein 12; Amniotic Fluid Binding Protein; Alpha-Pregnancy-Associated Endometrial Globulin; Growth Hormone Independent-Binding Protein
Assay Type: Sandwich
Sensitivity: 0.065 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Endocrinology;Cardiovascular biology;
Uniprot ID: P08833
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IGFBP1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IGFBP1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IGFBP1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IGFBP1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.201 2.106
5.00 1.593 1.498
2.50 1.088 0.993
1.25 0.728 0.633
0.63 0.632 0.537
0.32 0.336 0.241
0.16 0.213 0.118
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IGFBP1 and the recovery rates were calculated by comparing the measured value to the expected amount of IGFBP1 in samples.
Matrix Recovery range Average
serum(n=5) 93-107% 100%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IGFBP1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-98% 93-106% 89-97% 85-94%
EDTA plasma(n=5) 79-96% 85-99% 79-93% 89-97%
Heparin plasma(n=5) 85-94% 87-101% 89-99% 85-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
辉县市| 南京市| 桑日县| 焦作市| 平顶山市| 灵丘县| 斗六市| 嘉善县| 漾濞| 体育| 遂溪县| 江永县| 乌兰浩特市| 额尔古纳市| 教育| 绥阳县| 青阳县| 郯城县| 花莲市| 辽中县| 大安市| 延川县| 吴江市| 文山县| 安平县| 安达市| 密云县| 商南县| 桑日县| 淮北市| 关岭| 吉安县| 象州县| 丘北县| 资源县| 滦南县| 绥江县| 塘沽区| 贵定县| 泾阳县| 平凉市|