免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠白介素10(IL10)酶聯(lián)免疫吸附檢測試劑盒
ELK1143
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Mouse IL10(Interleukin 10) ELISA Kit
Reactivity: Mouse
Alternative Names: IL-10;CSIF; IL10A; TGIF; Cytokine Synthesis Inhibitory Factor
Assay Type: Sandwich
Sensitivity: 3 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P18893
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse IL10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse IL10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse IL10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse IL10 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.126 2.040
250.00 1.673 1.587
125.00 1.128 1.042
62.50 0.901 0.815
31.25 0.614 0.528
15.63 0.403 0.317
7.82 0.256 0.170
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IL10 and the recovery rates were calculated by comparing the measured value to the expected amount of IL10 in samples.
Matrix Recovery range Average
serum(n=5) 86-97% 92%
EDTA plasma(n=5) 84-103% 96%
Heparin plasma(n=5) 82-96% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL10 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 93-101% 85-98% 90-101%
EDTA plasma(n=5) 91-99% 83-97% 87-105% 87-99%
Heparin plasma(n=5) 85-90% 83-96% 95-102% 88-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
梓潼县| 蒙城县| 朝阳区| 阿拉善右旗| 绥芬河市| 灵璧县| 方城县| 休宁县| 塔城市| 田东县| 无锡市| 万载县| 清水县| 莎车县| 滨州市| 资中县| 中宁县| 和静县| 三都| 确山县| 文水县| 洪泽县| 新乡市| 南召县| 鞍山市| 兴业县| 九江市| 迁西县| 合川市| 望都县| 旌德县| 依兰县| 江门市| 嵩明县| 乐亭县| 泊头市| 大宁县| 旺苍县| 搜索| 琼海市| 潢川县|