免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人單核細(xì)胞趨化蛋白3(MCP3)酶聯(lián)免疫吸附檢測試劑盒
ELK1167
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human MCP3(Monocyte Chemotactic Protein 3) ELISA Kit
Reactivity: Human
Alternative Names: CCL7; FIC; MARC; NC28; MCP3; SCYA7; Chemokine C-C-Motif Ligand 7; Small Inducible Cytokine A7; Monocyte Chemoattractant Protein 3
Assay Type: Sandwich
Sensitivity: 6.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: P80098
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MCP3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MCP3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MCP3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MCP3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.164 2.011
500.00 1.682 1.529
250.00 1.132 0.979
125.00 0.872 0.719
62.50 0.508 0.355
31.25 0.301 0.148
15.63 0.226 0.073
0.00 0.153 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MCP3 and the recovery rates were calculated by comparing the measured value to the expected amount of MCP3 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 78-90% 84%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MCP3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-102% 92-101% 88-102% 87-102%
EDTA plasma(n=5) 92-101% 87-98% 85-92% 79-96%
Heparin plasma(n=5) 86-96% 93-104% 89-97% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
阳春市| 习水县| 永吉县| 恭城| 安乡县| 富锦市| 安义县| 荣昌县| 康马县| 普定县| 商城县| 奉节县| 永川市| 九龙城区| 汤原县| 南开区| 凌源市| 赤壁市| 石泉县| 饶平县| 开化县| 巴马| 乌拉特中旗| 仪征市| 视频| 洱源县| 红原县| 永清县| 张家界市| 松阳县| 长葛市| 岳普湖县| 江津市| 荥经县| 民勤县| 马鞍山市| 大余县| 邓州市| 皋兰县| 梨树县| 读书|