免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人組織金屬蛋白酶抑制因子4(TIMP4)酶聯(lián)免疫吸附檢測試劑盒
ELK1189
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TIMP4(Tissue Inhibitors Of Metalloproteinase 4) ELISA Kit
Reactivity: Human
Alternative Names: TIMP Metallopeptidase Inhibitor 4; Tissue Inhibitor of Metalloproteinases 4
Assay Type: Sandwich
Sensitivity: 0.058 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Cardiovascular biology;
Uniprot ID: Q99727
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TIMP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TIMP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TIMP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TIMP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.997 1.914
5.00 1.579 1.496
2.50 1.043 0.960
1.25 0.792 0.709
0.63 0.651 0.568
0.32 0.301 0.218
0.16 0.232 0.149
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TIMP4 and the recovery rates were calculated by comparing the measured value to the expected amount of TIMP4 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 85-98% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TIMP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 95-107% 87-102%
EDTA plasma(n=5) 88-102% 86-97% 89-97% 79-95%
Heparin plasma(n=5) 81-94% 96-105% 92-103% 82-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
拉萨市| 吴桥县| 弥渡县| 林芝县| 上高县| 娄烦县| 安康市| 平湖市| 宾阳县| 平顺县| 衡山县| 丰宁| 永新县| 靖边县| 汤阴县| 高台县| 远安县| 环江| 南安市| 同仁县| 靖宇县| 平度市| 阿拉尔市| 平乡县| 江油市| 道真| 禄丰县| 时尚| 杭锦后旗| 灵丘县| 抚州市| 边坝县| 湖北省| 灵丘县| 治多县| 张家川| 习水县| 汝城县| 襄汾县| 禄丰县| 湟中县|