免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人尿激酶型纖溶酶原激活因子(uPA)酶聯(lián)免疫吸附檢測試劑盒
ELK1192
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human uPA(Plasminogen Activator, Urokinase) ELISA Kit
Reactivity: Human
Alternative Names: PLAU; ATF; URK; UK; UP-A; Abbokinase; Urokinase-Type Plasminogen Activator
Assay Type: Sandwich
Sensitivity: 6.8 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human uPA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human uPA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human uPA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human uPA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.135 2.053
500.00 1.562 1.480
250.00 1.013 0.931
125.00 0.847 0.765
62.50 0.474 0.392
31.25 0.324 0.242
15.63 0.234 0.152
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant uPA and the recovery rates were calculated by comparing the measured value to the expected amount of uPA in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 87-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of uPA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 83-97% 81-103% 89-101%
EDTA plasma(n=5) 79-91% 95-104% 93-102% 79-94%
Heparin plasma(n=5) 87-98% 92-104% 82-96% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
同仁县| 新田县| 思南县| 宣汉县| 旅游| 岑溪市| 堆龙德庆县| 锡林浩特市| 临泽县| 铁岭市| 佛冈县| 蓬安县| 武强县| 平顶山市| 仁布县| 库车县| 花垣县| 宝山区| 枝江市| 武宣县| 苍南县| 岢岚县| 博罗县| 兰州市| 广昌县| 安丘市| 乐业县| 石屏县| 台州市| 道孚县| 甘德县| 呼伦贝尔市| 华坪县| 察雅县| 茶陵县| 奇台县| 青海省| 建德市| 拜泉县| 新兴县| 岗巴县|