人糖抗原19-9(CA19-9)酶聯(lián)免疫吸附檢測試劑盒
ELK1198
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human CA19-9(Carbohydrate Antigen 19-9) ELISA Kit
Reactivity: Human
Alternative Names: sialylated Lewis(a)Antigen; Cancer Antigen 19-9
Assay Type: Sandwich
Sensitivity: 0.28 U/mL
Standard: 50 U/mL
Detection Range: 0.79-50 U/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Hepatology;Gastroenterology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CA19-9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CA19-9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CA19-9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CA19-9 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (U/mL) OD Corrected OD
50.00 1.882 1.796
25.00 1.517 1.431
12.50 1.035 0.949
6.25 0.782 0.696
3.13 0.541 0.455
1.57 0.354 0.268
0.79 0.232 0.146
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CA19-9 and the recovery rates were calculated by comparing the measured value to the expected amount of CA19-9 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 90-103% 96%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CA19-9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 95-106% 83-98% 93-105%
EDTA plasma(n=5) 88-101% 90-98% 92-106% 85-97%
Heparin plasma(n=5) 91-104% 82-96% 88-101% 90-99%