免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠脂聯(lián)素(ADP)酶聯(lián)免疫吸附檢測試劑盒
ELK1234
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻

Product name: Mouse ADP(Adiponectin) ELISA Kit
Reactivity: Mouse
Alternative Names: GBP28; ApM1; AdipoQ; Acrp30; ACDC; APM1; C1Q And Collagen Domain Containing; Adipocyte Complement-Related Protein Of 30 KDa; Adipose Most Abundant Gene Transcript 1
Assay Type: Sandwich
Sensitivity: 14.2 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Infection immunity;Cardiovascular biology;
Uniprot ID: Q60994
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ADP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ADP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ADP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ADP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.105 2.034
1000.00 1.700 1.629
500.00 1.143 1.072
250.00 0.838 0.767
125.00 0.496 0.425
62.50 0.352 0.281
31.25 0.152 0.081
0.00 0.071 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADP and the recovery rates were calculated by comparing the measured value to the expected amount of ADP in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 92-105% 98%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 93-102% 79-94% 87-98%
EDTA plasma(n=5) 86-93% 91-105% 87-98% 89-94%
Heparin plasma(n=5) 91-99% 83-89% 88-104% 97-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
仁布县| 嘉鱼县| 湖北省| 蒙阴县| 抚松县| 秦安县| 石柱| 桂林市| 巴塘县| 平果县| 台南市| 津南区| 金乡县| 凌源市| 吉木萨尔县| 尚义县| 潮州市| 酒泉市| 新宾| 梁山县| 安平县| 关岭| 新巴尔虎右旗| 砀山县| 杭锦后旗| 平乡县| 南雄市| 旬邑县| 库车县| 左贡县| 舟山市| 南溪县| 海伦市| 景宁| 东阿县| 泽州县| 新乡市| 东兴市| 辽中县| 长乐市| 莱西市|