免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠肝素結(jié)合性表皮生長因子(HBEGF)酶聯(lián)免疫吸附檢測試劑盒
ELK1299
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse HBEGF(Heparin Binding Epidermal Growth Factor Like Growth Factor) ELISA Kit
Reactivity: Mouse
Alternative Names: HB-EGF; DTR; DTS; DTSF; HEGFL; Diphtheria Toxin Receptor; Proheparin-binding EGF-like growth factor; Diphtheria toxin receptor
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: Q06186
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse HBEGF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse HBEGF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse HBEGF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse HBEGF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.126 2.035
500.00 1.741 1.650
250.00 1.185 1.094
125.00 0.866 0.775
62.50 0.596 0.505
31.25 0.366 0.275
15.63 0.315 0.224
0.00 0.091 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HBEGF and the recovery rates were calculated by comparing the measured value to the expected amount of HBEGF in samples.
Matrix Recovery range Average
serum(n=5) 94-105% 98%
EDTA plasma(n=5) 94-107% 100%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HBEGF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 96-105% 85-93% 89-97%
EDTA plasma(n=5) 95-104% 87-96% 88-101% 82-95%
Heparin plasma(n=5) 79-92% 88-96% 77-91% 85-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
水富县| 昌都县| 平度市| 赤峰市| 老河口市| 鸡西市| 陆川县| 荥经县| 东丽区| 昔阳县| 阆中市| 新和县| 泗阳县| 西宁市| 雷山县| 道真| 衡阳市| 五原县| 甘南县| 台南县| 星座| 天峨县| 永定县| 朝阳区| 霍城县| 乌恰县| 大连市| 达日县| 炎陵县| 连南| 法库县| 常熟市| 奉节县| 正蓝旗| 巴彦淖尔市| 霍邱县| 正蓝旗| 且末县| 昌都县| 乌兰察布市| 饶河县|