免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠髓細(xì)胞觸發(fā)受體1(TREM1)酶聯(lián)免疫吸附檢測試劑盒
ELK1305
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse TREM1(Triggering Receptor Expressed On Myeloid Cells 1) ELISA Kit
Reactivity: Mouse
Alternative Names: CD354; Triggering Receptor Expressed On Monocytes-1
Assay Type: Sandwich
Sensitivity: 6.7 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: Q9JKE2
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse TREM1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse TREM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse TREM1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse TREM1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.105 2.034
500.00 1.609 1.538
250.00 1.147 1.076
125.00 0.738 0.667
62.50 0.536 0.465
31.25 0.357 0.286
15.63 0.192 0.121
0.00 0.071 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TREM1 and the recovery rates were calculated by comparing the measured value to the expected amount of TREM1 in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 92-107% 99%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TREM1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 86-92% 87-93% 95-103%
EDTA plasma(n=5) 91-98% 79-93% 92-101% 82-90%
Heparin plasma(n=5) 85-92% 80-96% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
当涂县| 高邑县| 澄城县| 紫金县| 阿拉善盟| 库尔勒市| 怀远县| 晋州市| 阿勒泰市| 刚察县| 伊川县| 洪洞县| 山东省| 阿拉善右旗| 浙江省| 冕宁县| 阿城市| 芒康县| 鹤壁市| 保亭| 宁安市| 衡山县| 巢湖市| 晋江市| 宣城市| 叙永县| 诸城市| 鹤峰县| 三都| 青海省| 儋州市| 滨州市| 泾源县| 盐亭县| 烟台市| 虎林市| 新化县| 保定市| 康乐县| 延吉市| 安阳县|