免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人半乳糖凝集素1(GAL1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1312
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human GAL1(Galectin 1) ELISA Kit
Reactivity: Human
Alternative Names: LGALS1; GBP; HLBP14; Galaptin; Lectin,Galactoside-Binding Soluble 1; 14 kDa laminin-binding protein; Lactose-binding lectin 1; Putative MAPK-activating protein PM12; S-Lac lectin
Assay Type: Sandwich
Sensitivity: 0.128 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;
Uniprot ID: P09382
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GAL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GAL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GAL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GAL1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
20.00 1.861 1.776
10.00 1.571 1.486
5.00 0.974 0.889
2.50 0.761 0.676
1.25 0.519 0.434
0.63 0.372 0.287
0.32 0.212 0.127
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GAL1 and the recovery rates were calculated by comparing the measured value to the expected amount of GAL1 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 89-103% 96%
Heparin plasma(n=5) 83-97% 90%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GAL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 86-92% 81-93% 79-95%
EDTA plasma(n=5) 85-94% 79-96% 98-105% 82-93%
Heparin plasma(n=5) 85-92% 96-104% 90-98% 80-92%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
华蓥市| 棋牌| 休宁县| 六盘水市| 赫章县| 来宾市| 瑞金市| 光山县| 巴林左旗| 宜兴市| 黄冈市| 乡宁县| 柯坪县| 德钦县| 咸丰县| 保山市| 巨鹿县| 拜泉县| 宁津县| 拉孜县| 辉县市| 通化县| 龙井市| 辉县市| 咸阳市| 合江县| 沂南县| 贵阳市| 全南县| 广东省| 曲阜市| 卓尼县| 镇赉县| 琼海市| 瑞安市| 乡宁县| 鄂州市| 项城市| 安多县| 资中县| 白朗县|