免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產品中心

人載脂蛋白B(APOB)酶聯(lián)免疫吸附檢測試劑盒
ELK1314
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human APOB(Apolipoprotein B) ELISA Kit
Reactivity: Human
Alternative Names: Apo-B; FLDB; Apo B-100; Apo B-48
Assay Type: Sandwich
Sensitivity: 0.072 μg/mL
Standard: 10 μg/mL
Detection Range: 0.16-10 μg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Endocrinology;Cardiovascular biology;Hepatology;Nutrition metabolism;
Uniprot ID: P04114
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human APOB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human APOB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human APOB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human APOB in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (μg/mL) OD Corrected OD
10.00 2.242 2.149
5.00 1.682 1.589
2.50 1.151 1.058
1.25 0.874 0.781
0.63 0.427 0.334
0.32 0.286 0.193
0.16 0.172 0.079
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant APOB and the recovery rates were calculated by comparing the measured value to the expected amount of APOB in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 83-95% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of APOB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 86-102% 91-103% 89-97%
EDTA plasma(n=5) 85-102% 87-96% 82-90% 92-101%
Heparin plasma(n=5) 79-92% 85-96% 80-98% 95-102%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
邵东县| 黄山市| 武威市| 铜鼓县| 东山县| 那坡县| 莱阳市| 秭归县| 登封市| 原阳县| 洛浦县| 濮阳县| 通辽市| 平罗县| 伊川县| 花垣县| 河北区| 韶关市| 安龙县| 修水县| 修水县| 六枝特区| 康平县| 岳普湖县| 瑞安市| 神木县| 城市| 永济市| 林芝县| 盐池县| 津市市| 长垣县| 五寨县| 修武县| 顺平县| 怀仁县| 南城县| 贺兰县| 原平市| 客服| 迁安市|