免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠白介素22(IL22)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1316
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse IL22(Interleukin 22) ELISA Kit
Reactivity: Mouse
Alternative Names: IL-22;ILTIF; Zcyto18; IL-TIF; IL-D110; TIFa; TIFIL-23;Cytokine Zcyto18; IL-10-Related T-Cell-Derived Inducible Factor
Assay Type: Sandwich
Sensitivity: 6.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;Pulmonology;Gastroenterology;
Uniprot ID: Q9JJY9
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse IL22. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse IL22. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse IL22, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse IL22 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.128 2.041
500.00 1.709 1.622
250.00 1.116 1.029
125.00 0.943 0.856
62.50 0.506 0.419
31.25 0.351 0.264
15.63 0.225 0.138
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IL22 and the recovery rates were calculated by comparing the measured value to the expected amount of IL22 in samples.
Matrix Recovery range Average
serum(n=5) 83-98% 90%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL22 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-99% 83-95% 98-104% 96-106%
EDTA plasma(n=5) 85-100% 84-98% 95-101% 88-102%
Heparin plasma(n=5) 86-93% 91-103% 87-98% 95-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
普格县| 双鸭山市| 汪清县| 利津县| 申扎县| 宜春市| 沁源县| 华安县| 化德县| 卫辉市| 西林县| 兴山县| 德兴市| 枣阳市| 界首市| 上思县| 怀来县| 蕲春县| 曲周县| 南召县| 灵山县| 江油市| 九江县| 海安县| 龙里县| 长兴县| 烟台市| 扶绥县| 兴安县| 新化县| 鄢陵县| 湘阴县| 肥东县| 中阳县| 辛集市| 长海县| 古浪县| 大足县| 双流县| 潮州市| 卢湾区|