免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人半胱氨酸蛋白酶抑制劑B(CSTB)酶聯(lián)免疫吸附檢測試劑盒
ELK1325
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human CSTB(Cystatin B) ELISA Kit
Reactivity: Human
Alternative Names: Cys-B; CST6; EPM1; PME; STFB; CPI-B; Stefin B; Liver thiol proteinase inhibitor
Assay Type: Sandwich
Sensitivity: 0.119 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Immune molecule;
Uniprot ID: P04080
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CSTB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CSTB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CSTB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CSTB in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.218 2.131
10.00 1.761 1.674
5.00 1.228 1.141
2.50 0.899 0.812
1.25 0.577 0.490
0.63 0.351 0.264
0.32 0.224 0.137
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CSTB and the recovery rates were calculated by comparing the measured value to the expected amount of CSTB in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CSTB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 96-103% 87-95% 83-92%
EDTA plasma(n=5) 95-104% 87-96% 89-101% 97-105%
Heparin plasma(n=5) 85-92% 88-96% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
麻阳| 琼海市| 杭锦后旗| 襄垣县| 尼木县| 锦州市| 许昌市| 兴国县| 枣强县| 平武县| 阿巴嘎旗| 晋宁县| 唐山市| 达孜县| 体育| 库伦旗| 牟定县| 马鞍山市| 剑阁县| 垫江县| 山东省| 宁安市| 永善县| 崇阳县| 太谷县| 丁青县| 兴和县| 神农架林区| 府谷县| 蓬莱市| 桂平市| 盐城市| 吴川市| 台东县| 杭锦旗| 河北省| 孝义市| 莫力| 保靖县| 元朗区| 安宁市|