免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠核因子κB亞基p105(NFKB-p105)酶聯(lián)免疫吸附檢測試劑盒
ELK1337
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Mouse NF-κBp105(Nuclear factor NF-kappa-B p105 subunit) ELISA Kit
Reactivity: Mouse
Alternative Names: NF-KB1; EBP-1; KBF1; NF-Kappa-B; NFKB-P105; NFKB-P50; Nuclear Factor Of Kappa Light Polypeptide Gene Enhancer In B-Cells 1; Nuclear factor NF-kappa-B p105 subunit; NFkB; Nuclear Factor Kappa B
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: P25799
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse NF-κBp105. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse NF-κBp105. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse NF-κBp105, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse NF-κBp105 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.809 1.707
5.00 1.348 1.246
2.50 0.933 0.831
1.25 0.647 0.545
0.63 0.506 0.404
0.32 0.377 0.275
0.16 0.216 0.114
0.00 0.102 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NF-κBp105 and the recovery rates were calculated by comparing the measured value to the expected amount of NF-κBp105 in samples.
Matrix Recovery range Average
serum(n=5) 85-99% 92%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 78-90% 84%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NF-κBp105 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 96-107% 89-103% 79-95%
EDTA plasma(n=5) 81-94% 78-90% 83-95% 86-97%
Heparin plasma(n=5) 80-94% 90-99% 87-103% 83-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
育儿| 得荣县| 三台县| 太仆寺旗| 滦平县| 桐梓县| 定南县| 南安市| 平潭县| 万荣县| 平乡县| 涿鹿县| 团风县| 综艺| 枣强县| 大兴区| 抚顺市| 乌拉特前旗| 荣成市| 津市市| 吉首市| 丰原市| 大城县| 吴忠市| 凤翔县| 葵青区| 方正县| 潜江市| 屯昌县| 北京市| 平乡县| 滦南县| 安陆市| 澄江县| 革吉县| 林周县| 山阳县| 卫辉市| 荔波县| 山阴县| 瑞安市|