免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

牛纖連蛋白(FN)酶聯(lián)免疫吸附檢測試劑盒
ELK1348
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Cattle FN(Fibronectin) ELISA Kit
Reactivity: Cattle
Alternative Names: FN1; CIG; FINC; LETS; MSF; GFND2; Anastellin; Migration-Stimulating Factor; Cold-Insoluble Globulin; Large, External, Transformation-Sensitive Protein
Assay Type: Sandwich
Sensitivity: 0.069 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Infection immunity;
Uniprot ID: P07589
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cattle FN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Cattle FN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cattle FN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cattle FN in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.153 2.051
5.00 1.724 1.622
2.50 1.132 1.030
1.25 0.864 0.762
0.63 0.532 0.430
0.32 0.388 0.286
0.16 0.225 0.123
0.00 0.102 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FN and the recovery rates were calculated by comparing the measured value to the expected amount of FN in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 94-107% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 78-96% 80-99% 89-97%
EDTA plasma(n=5) 85-101% 87-103% 84-92% 78-90%
Heparin plasma(n=5) 91-98% 83-101% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
茌平县| 佛冈县| 上犹县| 惠水县| 镇雄县| 临湘市| 泉州市| 息烽县| 东明县| 双鸭山市| 湘乡市| 深州市| 星子县| 常熟市| 班玛县| 安阳市| 澜沧| 土默特左旗| 仙居县| 东方市| 慈溪市| 曲阳县| 项城市| 自治县| 潞城市| 霍林郭勒市| 忻州市| 贡觉县| 多伦县| 肇庆市| 玉龙| 新宾| 丰原市| 大冶市| 临武县| 吉安县| 霸州市| 福鼎市| 临颍县| 大足县| 潢川县|