免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠乳脂球表皮生長因子8(MFGE8)酶聯(lián)免疫吸附檢測試劑盒
ELK1379
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse MFGE8(Milk Fat Globule EGF Factor 8) ELISA Kit
Reactivity: Mouse
Alternative Names: HMFG; MFGM; SED1; BA46; EDIL1; OAcGD3S; SPAG10; hP47; Medin; Lactadherin; Sperm Associated Antigen 10; Sperm Surface Protein hP47; Milk fat globule-EGF factor 8
Assay Type: Sandwich
Sensitivity: 6 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;
Uniprot ID: P21956
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse MFGE8. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse MFGE8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse MFGE8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse MFGE8 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.274 2.208
500.00 1.697 1.631
250.00 1.186 1.120
125.00 0.891 0.825
62.50 0.557 0.491
31.25 0.326 0.260
15.63 0.212 0.146
0.00 0.066 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MFGE8 and the recovery rates were calculated by comparing the measured value to the expected amount of MFGE8 in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MFGE8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-106% 86-99% 78-95% 89-97%
EDTA plasma(n=5) 85-94% 87-96% 92-101% 82-98%
Heparin plasma(n=5) 85-102% 83-96% 87-98% 82-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
丁青县| 仁布县| 浮梁县| 金乡县| 沙河市| 化隆| 芜湖市| 金沙县| 湛江市| 常熟市| 阳原县| 卓尼县| 多伦县| 神池县| 井陉县| 封丘县| 辽宁省| 翁牛特旗| 新民市| 英德市| 芜湖市| 南丰县| 沙洋县| 县级市| 仲巴县| 永胜县| 南昌县| 台东县| 磐石市| 黑山县| 西平县| 常熟市| 习水县| 长岭县| 霍邱县| 定边县| 高要市| 祥云县| 马关县| 额尔古纳市| 凤山县|