免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠骨成型蛋白2(BMP2)酶聯(lián)免疫吸附檢測試劑盒
ELK1406
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Mouse BMP2(Bone Morphogenetic Protein 2) ELISA Kit
Reactivity: Mouse
Alternative Names: BMP2A; BMP-2A; Hemochromatosis Modifier
Assay Type: Sandwich
Sensitivity: 6.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Developmental science;Bone metabolism;
Uniprot ID: P21274
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse BMP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse BMP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse BMP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse BMP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.136 2.068
500.00 1.629 1.561
250.00 1.115 1.047
125.00 0.757 0.689
62.50 0.421 0.353
31.25 0.257 0.189
15.63 0.174 0.106
0.00 0.068 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant BMP2 and the recovery rates were calculated by comparing the measured value to the expected amount of BMP2 in samples.
Matrix Recovery range Average
serum(n=5) 85-103% 94%
EDTA plasma(n=5) 95-105% 100%
Heparin plasma(n=5) 93-101% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 85-94% 87-96% 85-97%
EDTA plasma(n=5) 85-94% 87-96% 92-101% 82-98%
Heparin plasma(n=5) 87-91% 85-93% 89-97% 85-93%