免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠血管內(nèi)皮細(xì)胞蛋白C受體(PROCR)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1412
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse PROCR(Protein C Receptor, Endothelial) ELISA Kit
Reactivity: Mouse
Alternative Names: CD201; CCCA ; CCD41; BA42O4.2; EPCR; Endothelial Protein C Receptor; Cell Cycle, Centrosome-Associated Protein; Activated Protein C Receptor
Assay Type: Sandwich
Sensitivity: 34 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;CD & Adhesion molecule;Hematology;
Uniprot ID: Q64695
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse PROCR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse PROCR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse PROCR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse PROCR in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 1.953 1.850
2500.00 1.593 1.490
1250.00 1.157 1.054
625.00 0.826 0.723
312.50 0.516 0.413
156.25 0.339 0.236
78.13 0.215 0.112
0.00 0.103 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PROCR and the recovery rates were calculated by comparing the measured value to the expected amount of PROCR in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 86-98% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PROCR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-98% 83-103% 98-105% 92-101%
EDTA plasma(n=5) 85-105% 87-98% 91-102% 86-102%
Heparin plasma(n=5) 86-93% 91-105% 87-99% 99-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
亚东县| 乐安县| 库尔勒市| 柳江县| 搜索| 喀喇| 前郭尔| 比如县| 罗源县| 安远县| 建平县| 呼和浩特市| 永德县| 吴江市| 白银市| 湘潭市| 即墨市| 绵阳市| 多伦县| 林口县| 宣汉县| 宁海县| 江北区| 荣昌县| 湖北省| 河东区| 额济纳旗| 凌云县| 北宁市| 鹤壁市| 曲水县| 博白县| 安顺市| 永定县| 余庆县| 阿瓦提县| 深泽县| 荃湾区| 杭锦旗| 若尔盖县| 密云县|