免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠纖連蛋白(FN)酶聯(lián)免疫吸附檢測試劑盒
ELK1420
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat FN(Fibronectin) ELISA Kit
Reactivity: Rat
Alternative Names: FN1; CIG; FINC; LETS; MSF; GFND2; Anastellin; Migration-Stimulating Factor; Cold-Insoluble Globulin; Large, External, Transformation-Sensitive Protein
Assay Type: Sandwich
Sensitivity: 2.81 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Infection immunity;
Uniprot ID: P04937
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat FN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat FN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat FN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat FN in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
400.00 1.857 1.774
200.00 1.315 1.232
100.00 0.998 0.915
50.00 0.791 0.708
25.00 0.495 0.412
12.50 0.329 0.246
6.25 0.175 0.092
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FN and the recovery rates were calculated by comparing the measured value to the expected amount of FN in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 91-99% 95%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 85-98% 95-104% 82-96%
EDTA plasma(n=5) 92-105% 83-92% 89-98% 85-94%
Heparin plasma(n=5) 86-97% 93-105% 82-93% 95-104%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
昌江| 察哈| 清水河县| 昌乐县| 双城市| 浑源县| 红原县| 冷水江市| 东平县| 利川市| 景泰县| 泊头市| 崇明县| 商南县| 平泉县| 舒兰市| 金门县| 镇康县| 莎车县| 兴和县| 喀什市| 芷江| 乐陵市| 台中市| 城市| 石首市| 诏安县| 揭西县| 民丰县| 莒南县| 隆昌县| 宁明县| 宁明县| 古交市| 水富县| 大冶市| 庆云县| 雅安市| 南岸区| 广昌县| 项城市|