免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人碳酸酐酶Ⅰ(CA1)酶聯(lián)免疫吸附檢測試劑盒
ELK1432
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CA1(Carbonic Anhydrase I) ELISA Kit
Reactivity: Human
Alternative Names: CA-I; CAI; Car1; CAB; Carbonic anhydrase B; Carbonate dehydratase I
Assay Type: Sandwich
Sensitivity: 0.65 pg/mL
Standard: 100 pg/mL
Detection Range: 1.57-100 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Bone metabolism;
Uniprot ID: P00915
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CA1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CA1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CA1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
100.00 1.908 1.807
50.00 1.628 1.527
25.00 1.136 1.035
12.50 0.896 0.795
6.25 0.553 0.452
3.13 0.362 0.261
1.57 0.216 0.115
0.00 0.101 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CA1 and the recovery rates were calculated by comparing the measured value to the expected amount of CA1 in samples.
Matrix Recovery range Average
serum(n=5) 85-99% 92%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 81-97% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CA1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-96% 85-99% 79-93% 89-97%
EDTA plasma(n=5) 85-94% 87-101% 89-99% 85-95%
Heparin plasma(n=5) 86-94% 93-102% 89-97% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
霍山县| 长垣县| 横峰县| 三江| 徐水县| 扶绥县| 明光市| 盐城市| 宁南县| 剑阁县| 德化县| 屏东市| 合山市| 桐梓县| 富民县| 鹰潭市| 双流县| 紫阳县| 九龙城区| 石狮市| 绥中县| 四会市| 荣昌县| 通化县| 安义县| 咸阳市| 嘉义县| 多伦县| 鸡东县| 阳春市| 惠安县| 积石山| 乌拉特中旗| 乌拉特中旗| 定西市| 阜南县| 平定县| 两当县| 镇巴县| 伊吾县| 张家口市|