免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠內(nèi)皮脂肪酶(LIPG)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1434
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat LIPG(Lipase, Endothelial) ELISA Kit
Reactivity: Rat
Alternative Names: EL; EDL; Endothelial Lipase; Endothelial cell-derived lipase
Assay Type: Sandwich
Sensitivity: 1.15 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;
Uniprot ID: Q8VBX1
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat LIPG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat LIPG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat LIPG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat LIPG in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
200.00 1.946 1.877
100.00 1.685 1.616
50.00 1.263 1.194
25.00 0.864 0.795
12.50 0.539 0.470
6.25 0.312 0.243
3.13 0.158 0.089
0.00 0.069 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LIPG and the recovery rates were calculated by comparing the measured value to the expected amount of LIPG in samples.
Matrix Recovery range Average
serum(n=5) 79-97% 88%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LIPG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-104% 86-98% 80-93% 89-97%
EDTA plasma(n=5) 85-94% 87-99% 85-101% 79-90%
Heparin plasma(n=5) 87-102% 82-91% 86-93% 81-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
通化市| 浪卡子县| 黄浦区| 永修县| 泸州市| 小金县| 三原县| 密山市| 垫江县| 北宁市| 屏山县| 本溪市| 抚远县| 石城县| 乌审旗| 景东| 镇江市| 邻水| 镇沅| 黔南| 丰台区| 金阳县| 邹城市| 岳池县| 西安市| 江源县| 绥棱县| 舒兰市| 南漳县| 广州市| 永胜县| 阜南县| 常山县| 运城市| 吉木萨尔县| 北宁市| 广水市| 东兰县| 福鼎市| 武功县| 兴和县|