免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠性激素結(jié)合球蛋白(SHBG)酶聯(lián)免疫吸附檢測試劑盒
ELK1443
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse SHBG(Sex Hormone Binding Globulin) ELISA Kit
Reactivity: Mouse
Alternative Names: ABP; TEBG; SBP; Sex steroid-binding protein; Testis-specific androgen-binding protein; Testosterone-estradiol-binding globulin; Testosterone-estrogen-binding globulin
Assay Type: Sandwich
Sensitivity: 13.2 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Reproductive science;
Uniprot ID: P97497
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SHBG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SHBG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SHBG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SHBG in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.207 2.125
1000.00 1.613 1.531
500.00 1.073 0.991
250.00 0.847 0.765
125.00 0.521 0.439
62.50 0.397 0.315
31.25 0.165 0.083
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SHBG and the recovery rates were calculated by comparing the measured value to the expected amount of SHBG in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 92%
EDTA plasma(n=5) 84-96% 90%
Heparin plasma(n=5) 96-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SHBG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 85-97% 85-94% 87-96%
EDTA plasma(n=5) 92-101% 82-98% 89-97% 85-93%
Heparin plasma(n=5) 86-96% 93-104% 89-97% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
武宣县| 互助| 沽源县| 龙门县| 荆门市| 甘孜| 平度市| 淄博市| 乐平市| 洛南县| 靖边县| 房山区| 北宁市| 南涧| 正安县| 崇信县| 海原县| 察雅县| 志丹县| 海门市| 保德县| 昔阳县| 南和县| 蒲江县| 突泉县| 汶上县| 德兴市| 南安市| 濮阳市| 和田县| 于都县| 五台县| 西峡县| 若羌县| 喀喇| 博野县| 客服| 旺苍县| 湄潭县| 彩票| 麻江县|