免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人水通道蛋白2(AQP2)酶聯(lián)免疫吸附檢測試劑盒
ELK1447
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human AQP2(Aquaporin 2, Collecting Duct) ELISA Kit
Reactivity: Human
Alternative Names: AQP-CD; WCH-CD; ADH water channel; Aquaporin-CD; Collecting duct water channel protein; Water channel protein for renal collecting duct
Assay Type: Sandwich
Sensitivity: 0.117 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates, urine and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Kidney biomarker;
Uniprot ID: P41181
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AQP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AQP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AQP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AQP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.948 1.854
10.00 1.593 1.499
5.00 1.182 1.088
2.50 0.933 0.839
1.25 0.468 0.374
0.63 0.308 0.214
0.32 0.256 0.162
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant AQP2 and the recovery rates were calculated by comparing the measured value to the expected amount of AQP2 in samples.
Matrix Recovery range Average
serum(n=5) 84-99% 91%
EDTA plasma(n=5) 87-102% 94%
Heparin plasma(n=5) 95-106% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AQP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 92-101% 82-98%
EDTA plasma(n=5) 87-96% 85-98% 89-102% 85-98%
Heparin plasma(n=5) 85-94% 87-101% 86-97% 88-95%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
湘潭县| 广安市| 岳阳县| 南陵县| 普定县| 达州市| 明水县| 寻甸| 闸北区| 玉溪市| 宜昌市| 黄梅县| 雷波县| 湘阴县| 北川| 陵川县| 沂源县| 灵川县| 黔西县| 平昌县| 蒲江县| 保靖县| 东安县| 平南县| 郓城县| 鹿邑县| 绥德县| 安仁县| 元朗区| 东丽区| 且末县| 贡山| 景泰县| 夏津县| 四川省| 静宁县| 宜春市| 沁阳市| 延津县| 陇南市| 新沂市|