免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人脂蛋白脂酶(LIPD)酶聯(lián)免疫吸附檢測試劑盒
ELK1459
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human LIPD(Lipase, Lipoprotein) ELISA Kit
Reactivity: Human
Alternative Names: LPL; Lipoprotein Lipase
Assay Type: Sandwich
Sensitivity: 0.226 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Cardiovascular biology;
Uniprot ID: P06858
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LIPD. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LIPD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LIPD, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LIPD in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
40.00 1.956 1.869
20.00 1.578 1.491
10.00 1.123 1.036
5.00 0.827 0.740
2.50 0.573 0.486
1.25 0.387 0.300
0.63 0.215 0.128
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LIPD and the recovery rates were calculated by comparing the measured value to the expected amount of LIPD in samples.
Matrix Recovery range Average
serum(n=5) 89-107% 98%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 82-94% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LIPD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 87-96% 85-96% 85-95%
EDTA plasma(n=5) 86-100% 93-108% 80-101% 87-96%
Heparin plasma(n=5) 79-96% 85-99% 79-93% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
清新县| 永州市| 锡林浩特市| 宜州市| 西和县| 张北县| 大石桥市| 土默特右旗| 桃源县| 郑州市| 望城县| 道真| 洪湖市| 郯城县| 徐州市| 葵青区| 天峨县| 双桥区| 阿坝县| 彭水| 珲春市| 承德市| 来安县| 鹰潭市| 富民县| 南平市| 定西市| 潮安县| 垫江县| 密山市| 隆安县| 潞西市| 阿拉善盟| 海盐县| 武邑县| 康马县| 玛纳斯县| 大洼县| 松江区| 衡山县| 神农架林区|