免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠周期素依賴性激酶抑制因子2A(CDKN2A)酶聯(lián)免疫吸附檢測試劑盒
ELK1461
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse CDKN2A(Cyclin Dependent Kinase Inhibitor 2A) ELISA Kit
Reactivity: Mouse
Alternative Names: P16; ARF; CDK4I; CMM2; INK4; INK4a; MLM; MTS1; TP16; P14; P14ARF; P16INK4a; P19; Melanoma P16; Cyclin-dependent kinase 4 inhibitor A; Multiple tumor suppressor 1
Assay Type: Sandwich
Sensitivity: 0.108 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Developmental science;
Uniprot ID: P51480
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CDKN2A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CDKN2A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CDKN2A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CDKN2A in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.172 2.079
10.00 1.586 1.493
5.00 1.296 1.203
2.50 0.861 0.768
1.25 0.559 0.466
0.63 0.387 0.294
0.32 0.235 0.142
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CDKN2A and the recovery rates were calculated by comparing the measured value to the expected amount of CDKN2A in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 84-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CDKN2A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 83-92% 89-98% 85-94%
EDTA plasma(n=5) 86-102% 87-96% 89-98% 83-103%
Heparin plasma(n=5) 96-105% 95-103% 95-103% 87-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
西安市| 依安县| 大庆市| 中卫市| 黔江区| 余江县| 封丘县| 古蔺县| 汝南县| 宁强县| 固阳县| 富阳市| 清水河县| 阿拉善右旗| 孝昌县| 温州市| 永修县| 宁德市| 潍坊市| 志丹县| 贡山| 吉木萨尔县| 高要市| 原平市| 建瓯市| 济阳县| 醴陵市| 武汉市| 新龙县| 平和县| 若羌县| 蓬溪县| 泾源县| 郯城县| 高台县| 韩城市| 莆田市| 绥阳县| 淳化县| 封丘县| 固始县|