免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠血紅素氧合酶1(HO1)酶聯(lián)免疫吸附檢測試劑盒
ELK1477
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Rat HO1(Heme Oxygenase 1, Decycling) ELISA Kit
Reactivity: Rat
Alternative Names: HMOX1; Hsp32; HMOX1D
Assay Type: Sandwich
Sensitivity: 0.065 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Cardiovascular biology;
Uniprot ID: P06762
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat HO1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat HO1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat HO1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat HO1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.038 1.947
5.00 1.621 1.530
2.50 1.231 1.140
1.25 0.838 0.747
0.63 0.457 0.366
0.32 0.302 0.211
0.16 0.203 0.112
0.00 0.091 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HO1 and the recovery rates were calculated by comparing the measured value to the expected amount of HO1 in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 83-98% 90%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HO1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-96% 92-104% 89-101% 85-97%
EDTA plasma(n=5) 93-102% 81-96% 93-106% 82-95%
Heparin plasma(n=5) 86-97% 83-96% 91-103% 96-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
丘北县| 尼玛县| 肇州县| 铁岭县| 洛浦县| 石河子市| 广饶县| 富宁县| 无锡市| 千阳县| 馆陶县| 葫芦岛市| 渭源县| 囊谦县| 扎鲁特旗| 隆尧县| 德庆县| 开远市| 湾仔区| 建瓯市| 雷波县| 普洱| 龙州县| 陵水| 无为县| 班戈县| 宜州市| 册亨县| 江北区| 丰都县| 东至县| 武强县| 铜梁县| 邓州市| 三明市| 郯城县| 遵义县| 阿拉善左旗| 梁平县| 芜湖市| 仙游县|