免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠甲胎蛋白(aFP)酶聯(lián)免疫吸附檢測試劑盒
ELK1482
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat aFP(Alpha-Fetoprotein) ELISA Kit
Reactivity: Rat
Alternative Names: A-FP; FETA; HPAFP; Alpha-Fetoglobulin; Alpha-1-fetoprotein
Assay Type: Sandwich
Sensitivity: 0.127 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Hepatology;
Uniprot ID: P02773
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat aFP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat aFP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat aFP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat aFP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.242 2.149
10.00 1.682 1.589
5.00 1.169 1.076
2.50 0.819 0.726
1.25 0.513 0.420
0.63 0.336 0.243
0.32 0.222 0.129
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant aFP and the recovery rates were calculated by comparing the measured value to the expected amount of aFP in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 96-109% 102%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of aFP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-93% 96-105% 87-98% 85-97%
EDTA plasma(n=5) 82-94% 85-96% 78-90% 91-99%
Heparin plasma(n=5) 80-92% 86-102% 87-103% 85-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
福建省| 揭西县| 宝应县| 时尚| 公安县| 吴堡县| 西昌市| 古丈县| 海城市| 许昌县| 台南县| 唐海县| 皋兰县| 和林格尔县| 河东区| 益阳市| 铜山县| 隆昌县| 合阳县| 德令哈市| 海门市| 安福县| 焦作市| 夏邑县| 福建省| 邹城市| 寿光市| 长乐市| 潞西市| 荆门市| 鄂温| 五原县| 津南区| 拜城县| 舒城县| 洛阳市| 济南市| 额尔古纳市| 双鸭山市| 沈丘县| 搜索|