免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠甲胎蛋白(aFP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1483
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse aFP(Alpha-Fetoprotein) ELISA Kit
Reactivity: Mouse
Alternative Names: A-FP; FETA; HPAFP; Alpha-Fetoglobulin; Alpha-1-fetoprotein
Assay Type: Sandwich
Sensitivity: 23.2 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Hepatology;
Uniprot ID: P02772
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse aFP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse aFP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse aFP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse aFP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
4000.00 2.128 2.041
2000.00 1.609 1.522
1000.00 1.174 1.087
500.00 0.861 0.774
250.00 0.556 0.469
125.00 0.351 0.264
62.50 0.225 0.138
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant aFP and the recovery rates were calculated by comparing the measured value to the expected amount of aFP in samples.
Matrix Recovery range Average
serum(n=5) 82-97% 89%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of aFP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-95% 88-102% 84-97% 89-107%
EDTA plasma(n=5) 78-92% 79-93% 94-106% 83-97%
Heparin plasma(n=5) 85-97% 90-99% 82-101% 93-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
图片| 山丹县| 云龙县| 资源县| 长沙县| 万安县| 许昌县| 上饶市| 文山县| 汪清县| 沭阳县| 土默特左旗| 南郑县| 类乌齐县| 临城县| 镇赉县| 阿拉尔市| 东山县| 芦溪县| 清新县| 大连市| 隆化县| 萍乡市| 二手房| 富蕴县| 曲松县| 峨边| 微山县| 油尖旺区| 海晏县| 阜南县| 靖西县| 黄浦区| 南开区| 江城| 四会市| 金秀| 陕西省| 石首市| 石屏县| 永年县|