免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人熱休克蛋白β2(HSPb2)酶聯(lián)免疫吸附檢測試劑盒
ELK1490
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human HSPb2(Heat Shock Protein Beta 2) ELISA Kit
Reactivity: Human
Alternative Names: HSP-B2; MKBP; HSP27; Heat Shock 27kDa Protein 2; DMPK-binding protein
Assay Type: Sandwich
Sensitivity: 0.265 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Tumor immunity;Developmental science;
Uniprot ID: Q16082
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HSPb2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HSPb2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HSPb2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HSPb2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
40.00 2.166 2.080
20.00 1.664 1.578
10.00 1.138 1.052
5.00 0.878 0.792
2.50 0.627 0.541
1.25 0.372 0.286
0.63 0.232 0.146
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HSPb2 and the recovery rates were calculated by comparing the measured value to the expected amount of HSPb2 in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 83-95% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPb2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-103% 83-94% 92-105% 89-97%
EDTA plasma(n=5) 85-97% 87-96% 82-95% 92-105%
Heparin plasma(n=5) 90-99% 95-106% 87-101% 82-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
清水河县| 江门市| 东海县| 苏州市| 突泉县| 宜昌市| 翁牛特旗| 团风县| 昭苏县| 沧源| 来安县| 衡东县| 云南省| 鲁山县| 梨树县| 土默特左旗| 扶绥县| 昆明市| 普洱| 文水县| 渝中区| 济阳县| 彭水| 灵川县| 太原市| 富阳市| 崇左市| 崇左市| 都江堰市| 积石山| 汝南县| 滨州市| 博爱县| 阿巴嘎旗| 龙川县| 礼泉县| 东阳市| 东乡| 平潭县| 绍兴县| 恩施市|