免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠內(nèi)皮型一氧化氮合酶(NOS3)酶聯(lián)免疫吸附檢測試劑盒
ELK1502
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse NOS3(Nitric Oxide Synthase 3, Endothelial) ELISA Kit
Reactivity: Mouse
Alternative Names: ECNOS; NOS III; E-NOS; C-NOS; ENOS; CNOS; Constitutive NOS
Assay Type: Sandwich
Sensitivity: 0.56 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Cardiovascular biology;
Uniprot ID: P70313
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse NOS3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse NOS3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse NOS3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse NOS3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.157 2.062
50.00 1.562 1.467
25.00 1.185 1.090
12.50 0.937 0.842
6.25 0.516 0.421
3.13 0.327 0.232
1.57 0.216 0.121
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NOS3 and the recovery rates were calculated by comparing the measured value to the expected amount of NOS3 in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 85-95% 90%
Heparin plasma(n=5) 83-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NOS3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-94% 96-105% 92-103% 82-96%
EDTA plasma(n=5) 88-97% 97-105% 81-93% 89-102%
Heparin plasma(n=5) 87-98% 92-105% 83-92% 89-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
平利县| 盐边县| 五家渠市| 商城县| 讷河市| 航空| 安吉县| 通江县| 丹凤县| 罗田县| 宜丰县| 涪陵区| 金湖县| 凤冈县| 嘉鱼县| 五大连池市| 罗甸县| 大同市| 邵阳市| 伊宁市| 永顺县| 高碑店市| 泽州县| 黄骅市| 溆浦县| 西平县| 时尚| 江油市| 肥城市| 建水县| 靖西县| 阿拉善左旗| 榕江县| 中宁县| 梓潼县| 九寨沟县| 兴海县| 永福县| 策勒县| 洛浦县| 沐川县|