免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠凝血因子Ⅱ(F2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1517
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat F2(Coagulation Factor II) ELISA Kit
Reactivity: Rat
Alternative Names: FII; TM; PT; Thrombin; Prothrombin; Pro-Thrombin; Activation peptide fragment 1; Activation peptide fragment 2
Assay Type: Sandwich
Sensitivity: 3.5 ng/mL
Standard: 500 ng/mL
Detection Range: 7.82-500 ng/mL
Sample Type: Serum
Assay Length: 3.5h
Research Area: Signal transduction;Hematology;
Uniprot ID: P18292
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat F2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat F2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat F2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat F2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
500.00 2.052 1.954
250.00 1.755 1.657
125.00 1.225 1.127
62.50 0.915 0.817
31.25 0.507 0.409
15.63 0.352 0.254
7.82 0.248 0.150
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant F2 and the recovery rates were calculated by comparing the measured value to the expected amount of F2 in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 78-90% 84%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of F2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-105% 95-107% 82-96%
EDTA plasma(n=5) 86-93% 91-105% 87-98% 99-102%
Heparin plasma(n=5) 93-102% 81-96% 93-106% 82-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
明光市| 古丈县| 永城市| 临泽县| 喀喇沁旗| 五台县| 安陆市| 永登县| 白玉县| 利津县| 色达县| 留坝县| 二手房| 霍城县| 成都市| 仁怀市| 钦州市| 天津市| 吉林省| 叶城县| 和林格尔县| 监利县| 南城县| 阿尔山市| 阿拉善左旗| 台前县| 兴文县| 二连浩特市| 金华市| 锦州市| 德令哈市| 清苑县| 泰安市| 台前县| 榕江县| 堆龙德庆县| 田林县| 娱乐| 茌平县| 林甸县| 祁东县|