免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人趨化因子C-X-C-基元受體3(CXCR3)酶聯(lián)免疫吸附檢測試劑盒
ELK1522
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CXCR3(Chemokine C-X-C-Motif Receptor 3) ELISA Kit
Reactivity: Human
Alternative Names: CD183; CKR-L2; CMKAR3; GPR9; IP10r; IP10-R; Mig-R; MigR; G Protein-Coupled Receptor 9; Interferon-inducible protein 10 receptor; IP-10 receptor
Assay Type: Sandwich
Sensitivity: 0.062 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule;
Uniprot ID: P49682
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CXCR3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CXCR3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CXCR3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CXCR3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.368 2.270
5.00 1.674 1.576
2.50 1.114 1.016
1.25 0.842 0.744
0.63 0.496 0.398
0.32 0.321 0.223
0.16 0.225 0.127
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CXCR3 and the recovery rates were calculated by comparing the measured value to the expected amount of CXCR3 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CXCR3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 83-97% 81-103% 89-101%
EDTA plasma(n=5) 87-96% 91-101% 87-98% 89-103%
Heparin plasma(n=5) 82-94% 85-96% 78-90% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
柳江县| 上杭县| 孟州市| 常宁市| 栾城县| 山东省| 海丰县| 宾川县| 筠连县| 嘉祥县| 崇明县| 六盘水市| 武川县| 来凤县| 平泉县| 彰化市| 澄江县| 陵水| 当雄县| 娄烦县| 城口县| 宁化县| 嘉荫县| 南通市| 宜宾市| 涞源县| 聂荣县| 筠连县| 清流县| 常山县| 南川市| 舞阳县| 桦南县| 福泉市| 肇源县| 汉源县| 长沙市| 浦江县| 叶城县| 甘肃省| 砚山县|