免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠C組著色性干皮病偶聯(lián)因子(XPC)酶聯(lián)免疫吸附檢測試劑盒
ELK1539
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse XPC(Xeroderma Pigmentosum, Complementation Group C) ELISA Kit
Reactivity: Mouse
Alternative Names: XP-C; XP3; XPCC; RAD4; Xeroderma Pigmentosum Group C Protein; DNA repair protein complementing XP-C cells
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Metabolic pathway;Tumor immunity;
Uniprot ID: P51612
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse XPC. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse XPC. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse XPC, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse XPC in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.038 1.952
5.00 1.624 1.538
2.50 1.216 1.130
1.25 0.847 0.761
0.63 0.593 0.507
0.32 0.318 0.232
0.16 0.179 0.093
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant XPC and the recovery rates were calculated by comparing the measured value to the expected amount of XPC in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of XPC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 93-103% 94-106% 91-101%
EDTA plasma(n=5) 89-95% 88-97% 86-92% 91-99%
Heparin plasma(n=5) 87-98% 83-94% 85-98% 85-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
梁山县| 博兴县| 荣成市| 湖口县| 乐山市| 略阳县| 岳阳县| 高阳县| 东光县| 天峨县| 长岛县| 曲麻莱县| 阿拉尔市| 盐边县| 河南省| 阿拉尔市| 铜鼓县| 栾城县| 炎陵县| 墨竹工卡县| 广灵县| 福泉市| 巫山县| 高密市| 忻州市| 天水市| 三都| 洛宁县| 洛隆县| 青冈县| 宜黄县| 灌阳县| 永川市| 万年县| 山西省| 阿荣旗| 江阴市| 洞头县| 沭阳县| 岱山县| 鹤庆县|