免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠凝血因子Ⅸ(F9)酶聯(lián)免疫吸附檢測試劑盒
ELK1561
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat F9(Coagulation Factor IX) ELISA Kit
Reactivity: Rat
Alternative Names: HEMB; FIX; GLA Domain; PTC; Anti Hemophilic Factor B; Christmas Factor; Plasma Thromboplastic Component; Christmas Disease; Hemophilia B
Assay Type: Sandwich
Sensitivity: 0.067 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Plasma.
Assay Length: 3.5h
Research Area: Signal transduction;Hematology;
Uniprot ID: P16296
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat F9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat F9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat F9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat F9 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.082 1.987
5.00 1.519 1.424
2.50 1.186 1.091
1.25 0.971 0.876
0.63 0.617 0.522
0.32 0.365 0.270
0.16 0.213 0.118
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant F9 and the recovery rates were calculated by comparing the measured value to the expected amount of F9 in samples.
Matrix Recovery range Average
serum(n=5) 93-107% 100%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of F9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-100% 84-98% 97-101% 88-96%
EDTA plasma(n=5) 85-92% 82-96% 87-105% 87-92%
Heparin plasma(n=5) 93-102% 86-92% 96-105% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江口县| 扶余县| 安岳县| 库车县| 石景山区| 柳河县| 商南县| 武定县| 谷城县| 常宁市| 马公市| 垫江县| 巴东县| 德钦县| 扬州市| 弥勒县| 南通市| 桃江县| 宁陵县| 赤水市| 浪卡子县| 城步| 奈曼旗| 平遥县| 万山特区| 平泉县| 澄江县| 云浮市| 泗阳县| 永嘉县| 子洲县| 南康市| 宜城市| 西贡区| 恩施市| 兴城市| 临沧市| 钦州市| 宜宾县| 赣州市| 珲春市|