小鼠含血管性血友病因子A域蛋白1(vWA1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1563
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse vWA1(Von Willebrand Factor A Domain Containing Protein 1) ELISA Kit
Reactivity: Mouse
Alternative Names: VWFA1; WARP
Assay Type: Sandwich
Sensitivity: 12.4 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Plasma.
Assay Length: 3.5h
Research Area: Hematology;
Uniprot ID: Q8R2Z5
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse vWA1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse vWA1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse vWA1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse vWA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 1.933 1.846
1000.00 1.522 1.435
500.00 1.143 1.056
250.00 0.827 0.740
125.00 0.545 0.458
62.50 0.332 0.245
31.25 0.211 0.124
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant vWA1 and the recovery rates were calculated by comparing the measured value to the expected amount of vWA1 in samples.
Matrix Recovery range Average
serum(n=5) 88-99% 93%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 80-97% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of vWA1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 97-106% 92-101% 82-90%
EDTA plasma(n=5) 85-92% 96-103% 87-98% 95-102%
Heparin plasma(n=5) 97-106% 86-92% 91-103% 89-97%