免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人心肌營(yíng)養(yǎng)素1(CT1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1567
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CT1(Cardiotrophin 1) ELISA Kit
Reactivity: Human
Alternative Names: CTF1
Assay Type: Sandwich
Sensitivity: 5.9 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Cardiovascular biology;
Uniprot ID: Q16619
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CT1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CT1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CT1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CT1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.168 2.081
500.00 1.609 1.522
250.00 1.165 1.078
125.00 0.861 0.774
62.50 0.473 0.386
31.25 0.324 0.237
15.63 0.258 0.171
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CT1 and the recovery rates were calculated by comparing the measured value to the expected amount of CT1 in samples.
Matrix Recovery range Average
serum(n=5) 77-95% 86%
EDTA plasma(n=5) 88-103% 95%
Heparin plasma(n=5) 92-106% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CT1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-91% 87-96% 83-101% 82-95%
EDTA plasma(n=5) 86-93% 88-92% 86-97% 90-101%
Heparin plasma(n=5) 91-99% 85-93% 82-95% 93-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
台东市| 桦川县| 灵宝市| 兰坪| 龙胜| 女性| 顺昌县| 肥城市| 商洛市| 化州市| 余姚市| 安塞县| 九龙城区| 金塔县| 道孚县| 甘德县| 特克斯县| 万山特区| 策勒县| 太白县| 镇沅| 德格县| 繁昌县| 门源| 五台县| 重庆市| 上栗县| 南京市| 静海县| 镇原县| 旅游| 武宣县| 洛阳市| 遂宁市| 桃源县| 石嘴山市| 利川市| 晋江市| 湘潭县| 竹山县| 洛宁县|