免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人糖原磷酸化酶L(PYGL)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1577
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PYGL(Glycogen Phosphorylase, Liver) ELISA Kit
Reactivity: Human
Alternative Names: GPLL; GPBB; Hers Disease; Glycogen Storage Disease Type VI
Assay Type: Sandwich
Sensitivity: 0.115 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Endocrinology;
Uniprot ID: P06737
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PYGL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PYGL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PYGL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PYGL in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.908 1.804
10.00 1.628 1.524
5.00 1.128 1.024
2.50 0.928 0.824
1.25 0.563 0.459
0.63 0.342 0.238
0.32 0.228 0.124
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PYGL and the recovery rates were calculated by comparing the measured value to the expected amount of PYGL in samples.
Matrix Recovery range Average
serum(n=5) 78-95% 86%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 80-96% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PYGL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 92-101% 87-96% 82-90%
EDTA plasma(n=5) 89-105% 90-101% 87-98% 85-92%
Heparin plasma(n=5) 78-92% 79-93% 91-98% 89-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
伊宁县| 蒙城县| 朝阳区| 抚顺县| 甘肃省| 将乐县| 盐源县| 合山市| 景德镇市| 江川县| 长乐市| 乌兰浩特市| 长泰县| 东宁县| 岚皋县| 左权县| 广灵县| 吴忠市| 柞水县| 柞水县| 满城县| 高淳县| 隆回县| 鹤庆县| 汾阳市| 盘锦市| 繁峙县| 榆社县| 西和县| 南部县| 卢湾区| 宣威市| 丰原市| 邯郸市| 太谷县| 襄樊市| 临海市| 得荣县| 嘉峪关市| 宁国市| 巴里|