免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠糖原磷酸化酶L(PYGL)酶聯(lián)免疫吸附檢測試劑盒
ELK1579
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse PYGL(Glycogen Phosphorylase, Liver) ELISA Kit
Reactivity: Mouse
Alternative Names: GPLL; GPBB; Hers Disease; Glycogen Storage Disease Type VI
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Endocrinology;
Uniprot ID: Q9ET01
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse PYGL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse PYGL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse PYGL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse PYGL in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.956 1.868
5.00 1.685 1.597
2.50 1.027 0.939
1.25 0.782 0.694
0.63 0.468 0.380
0.32 0.332 0.244
0.16 0.216 0.128
0.00 0.088 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PYGL and the recovery rates were calculated by comparing the measured value to the expected amount of PYGL in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PYGL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 87-96% 92-101% 82-90%
EDTA plasma(n=5) 85-92% 89-96% 90-98% 87-98%
Heparin plasma(n=5) 88-99% 86-92% 89-103% 97-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
河曲县| 河间市| 罗源县| 商丘市| 湖北省| 桐乡市| 句容市| 青阳县| 呼和浩特市| 麦盖提县| 齐河县| 阳原县| 吉隆县| 宾川县| 山阳县| 宜宾市| 万山特区| 镇平县| 香格里拉县| 云阳县| 奉贤区| 镇巴县| 马山县| 延川县| 遵化市| 库伦旗| 阿拉善左旗| 罗江县| 隆化县| 兴和县| 昭苏县| 潞西市| 会昌县| 海门市| 陵水| 镇江市| 张北县| 三河市| 增城市| 余姚市| 怀安县|