免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胃泌素抑制肽(GIP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1580
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human GIP(Gastric Inhibitory Polypeptide) ELISA Kit
Reactivity: Human
Alternative Names: Incretin hormone;? Glucose Dependent Insulinotropic Peptide
Assay Type: Competitive Inhibition
Sensitivity: 23.9 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;Gastroenterology;Hormone metabolism;
Uniprot ID: P09681
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human GIP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GIP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GIP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 0.211
2500.00 0.352
1250.00 0.557
625.00 0.861
312.50 1.152
156.25 1.511
78.13 1.755
0.00 2.132

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GIP and the recovery rates were calculated by comparing the measured value to the expected amount of GIP in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 96-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GIP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-85% 87-96% 82-95% 89-103%
EDTA plasma(n=5) 95-102% 96-104% 87-98% 95-107%
Heparin plasma(n=5) 82-94% 85-96% 78-90% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
德昌县| 策勒县| 鄂托克前旗| 娄底市| 游戏| 津南区| 凭祥市| 志丹县| 介休市| 乌鲁木齐市| 遵义市| 东方市| 绥滨县| 香河县| 安岳县| 吉木乃县| 枝江市| 建德市| 泾阳县| 鄢陵县| 寿阳县| 遂平县| 达拉特旗| 平利县| 安新县| 安庆市| 甘肃省| 华池县| 华池县| 尉氏县| 双鸭山市| 安庆市| 浪卡子县| 施秉县| 灯塔市| 威宁| 凤山县| 垣曲县| 依兰县| 乳山市| 珠海市|